Applicable conditions
- Acidic or alkaline gases
- Water-soluble odors
- Oil mist, droplets and some dust
- Pretreatment to protect downstream RAO equipment
Core technology
High-intensity foam scrubbing — Absorption, chemical reaction and capture of oil mist and particles take place in a dynamic foam mass-transfer zone.

The liquid chemistry, materials, stages and dosing must match the pollutants. Poorly soluble, non-reactive, low-concentration VOCs should not rely on scrubbing alone.
Install before RAO to control oil mist, particles and water-soluble components, or after RAO to absorb polar oxidation intermediates.
PROCESS & OPERATION
JETA combines counter-current gas–liquid contact, absorption, reaction and capture of some droplets and particles. Single- or two-stage layouts and circulation liquids are configured around the target compounds.
Explore testing & validation ↗
Exhaust meets the liquid jet in a turbulent reaction zone.
Droplet breakup and surface renewal promote contact for absorption and reaction.
Select the liquid chemistry, dosing, make-up water and blowdown strategy.
Remove entrained droplets before downstream treatment or exhaust discharge.
Select acidic, alkaline or other suitable reaction liquids; track concentration, pH and replacement intervals.
Evaluate PP, FRP or stainless steel against temperature, corrosion and chemical compatibility.
Use separate stages for mixed compounds and define inlet conditions for downstream equipment.
LET’S TALK ABOUT YOUR PROJECT
Share your airflow, temperature, humidity, target pollutants or cleanliness requirements. We will help assess suitable equipment and system configurations.