Source treatment equipment

JETA1000-2

In-situ foam absorption — Combines two foam-enhanced mass-transfer modules, liquid circulation and a fan for absorbable or reactive compounds near kilns and workstations.

JETA1000-2

Applicable conditions

  • Distributed kilns, workstations or individual lines
  • Absorbable or reactive odor compounds
  • Exhaust containing oil mist, droplets or some particles
  • Batch production with line-by-line operation

Operating limits

Liquid chemistry, construction materials, stage count and mist removal must match corrosiveness, temperature and composition. Poorly soluble, non-reactive VOCs require validation and potentially further treatment.

System combinations

Use with local capture, short ducts and existing clean-exhaust headers, or as a front-end unit to reduce the airflow and load of a centralized system.

PROCESS & OPERATION

Two absorption modules close to the source.

JETA1000-2 combines foam-enhanced mass transfer, two absorption modules, liquid circulation and a fan. Materials and liquids are selected for absorbable or reactive kiln and workstation exhaust.

Explore testing & validation
Gas–liquid contact within an absorption module; actual two-module layouts are project-specific
Gas–liquid contact within an absorption module; actual two-module layouts are project-specific
  1. 01

    Assess absorption

    Review the compounds and liquid chemistry, with trials where needed.

  2. 02

    Configure two modules

    Define each module’s role, circulation loop and mist removal.

  3. 03

    Integrate near the kiln

    Coordinate short ducts, the fan, servicing and drainage.

  4. 04

    Link to kiln operation

    Set controls around kiln operation and shutdown purge requirements.

Chemistry and materials

Confirm liquids, wetted materials and seals for the temperature and corrosiveness.

Liquid maintenance

Plan make-up, dosing, blowdown and circulation-system cleaning.

Downstream support

Validate further treatment or backup stages for compounds that are difficult to absorb.

LET’S TALK ABOUT YOUR PROJECT

Start with your air requirements.

Share your airflow, temperature, humidity, target pollutants or cleanliness requirements. We will help assess suitable equipment and system configurations.